[[:検証/ログサーバ]]


#norelated
#topicpath
#contents

#memo(https://www1.ntt-east.ipxp/gyoumukansa/guide-top/kaizen2007.html\nhttps://www1.ntt-east.ipxp/gyoumukansa/guide-top/kansa2007.html\nhttp://www1.ntt-east.ipxp/csd/syogai/index.html\nhttp://www1.ntt-east.ipxp/csd/syonai/index.html\nhttp://www1.ntt-east.ipxp/csd/kosyo/framepage1.htm\nhttp://www1.ntt-east.ipxp/csd/shien/home.html\nhttp://www1.ntt-east.ipxp/csd/tougou-setsubi/download1.htm\nhttp://www1.ntt-east.ipxp/cas/02/members/index.htm\nhttp://www1.ntt-east.ipxp/cas/02/restdata/index.htm\nhttp://www1.ntt-east.ipxp/diversity/\n\nmore /etc/sysconfig/network-scripts/route-eth1\n10.159.212.0/255.255.255.0      via 10.159.213.129\n10.159.213.0/255.255.255.0      via 10.159.213.129\n10.159.214.0/255.255.255.0      via 10.159.213.129\n10.159.215.0/255.255.255.0      via 10.159.213.129\n10.159.216.0/255.255.255.0      via 10.159.213.129\n10.40.255.128/255.255.255.192   via 10.159.213.129\n10.0.0.0/255.255.255.0          via 10.159.213.129\n172.16.0.0/255.255.0.0          via 10.159.213.129\n\n# more /etc/hosts\n127.0.0.1   localhost localhost.localdomain localhost4 localhost4.localdomain4\n121.119.249.7   mix1    mix1.   mix1.ntt-east.co.jp\n192.168.163.179 mix1-c mix1-c. mix1-c.kanshi.local\n\n10.159.213.152 www1.ntt-east.ipxp       #ZAKI\n\n# kanshi\n10.159.216.40   ari-mlog01      kanshi.local #dummy mx record ari-mlog01\n10.159.213.12   kra-mlog01\n10.159.215.12   sen-mlog01\n10.159.213.15   kra-madm01\n10.159.215.15   sen-madm01\n10.159.216.45   ari-madm01\n#\n# ESIGHT host table\n#\n121.119.249.1   ns1     ns1.ntt-east.co.jp\n121.119.249.2   ns2     ns2.ntt-east.co.jp\n121.119.249.4   vscan1  vscan1.ntt-east.co.jp\n121.119.249.5   vscan2  vscan2.ntt-east.co.jp\n121.119.249.6   mix     mix.ntt-east.co.jp\n121.119.249.8   mix2    mix2.ntt-east.co.jp\n121.119.249.9   mcrypt  mcrypt.ntt-east.co.jp\n121.119.249.10  mcrypt1 mcrypt1.ntt-east.co.jp\n121.119.249.11  mcrypt2 mcrypt2.ntt-east.co.jp\n121.119.249.14  vscan   vscan.ntt-east.co.jp\n121.119.249.20  relay-gw1\n121.119.249.21  relay-gw2\n121.119.249.22  relay-gw3\n121.119.249.23  relay-gw4\n121.119.249.24  fh_ra\n121.119.249.27  lb1\n121.119.249.28  lb2\n121.119.249.30  sw-v34\n#\n# Housing host table\n#\n192.168.164.11  w2wb4000\n192.168.164.12  w2wb4001\n192.168.164.34  main1\n192.168.164.35  main2\n192.168.164.36  komail\n192.168.164.37  ksub\n10.5.197.34     main1n\n10.5.197.35     main2n\n121.119.249.145 ksubn\n121.119.249.163 mp.ntt-east.co.jp\n192.168.164.137 mp\n121.119.249.163 azb.nttls.co.jp\n192.168.164.137 azb.nttls.co.jp\n192.168.164.161 evs.ntt-east.co.jp\n192.168.164.184 flets.com\n192.168.165.56  web116.jp\n192.168.165.148 flets.com\n192.168.165.149 flets.com\n10.5.199.193    flets.com\n10.5.199.194    flets.com\n10.105.29.52    mail.saitai.ntt-east.co.jp\n192.168.164.227 mm.ite-dmail.ntt-east.co.jp\n192.168.164.228 mm.ite-dmail.ntt-east.co.jp\n192.168.164.245 mm.dmail.ntt-east.co.jp\n192.168.164.246 mm.dmail.ntt-east.co.jp\n10.105.29.41    pcp.ntt-east.co.jp\n121.119.249.171 nmrs.ntt-east.co.jp\n121.119.249.174 nmrs.ntt-east.co.jp\n121.119.249.176 nm.nmrs.ntt-east.co.jp\n#10.5.196.226   c1s01r0otwb01u0.ipd.ntt-east.co.jp\n#10.5.196.228   c1s01r0otwb01u0.ipd.ntt-east.co.jp\n10.5.196.226    C4S01R0ARWB01E0.ipd.ntt-east.co.jp\n10.5.196.226    C4S01R0ARWB02E0.ipd.ntt-east.co.jp\n10.5.196.227    C4S01R0ARWB01E0.ipd.ntt-east.co.jp\n10.5.196.228    C4S01R0ARWB02E0.ipd.ntt-east.co.jp\n10.5.199.3      bs.ntt-east.co.jp\n10.5.199.4      bs.ntt-east.co.jp\n10.5.199.8      bs.ntt-east.co.jp\n10.5.199.97     www1.ntt-east.co.jp\n10.5.199.98     www1.ntt-east.co.jp\n10.5.199.99     www1.ntt-east.co.jp\n121.119.249.221 swu.setsubi-info.ntt-east.co.jp\n10.5.199.129    kmcdockyoyaku.ntt-east.co.jp\n10.5.199.130    kmcdockyoyaku.ntt-east.co.jp\n10.5.199.65     anniv-denpo.ntt-east.co.jp\n10.5.199.66     anniv-denpo.ntt-east.co.jp\n10.5.199.225    hikariweb.ntt-east.co.jp\n10.5.199.226    hikariweb.ntt-east.co.jp\n10.5.199.227    hikariweb.ntt-east.co.jp\n121.119.249.199 ob-saitama.ntt-east.co.jp\n121.119.249.196 niigata-happy-town.ntt-east.co.jp\n121.119.249.196 hikaripark.ntt-east.co.jp\n121.119.249.207 fletsmembers-community.ntt-east.co.jp\n121.119.249.205 ibaraki-happy-town.ntt-east.co.jp\n121.119.249.204 iwate-happy-town.ntt-east.co.jp\n121.119.249.198 gunma-happy-town.ntt-east.co.jp\n121.119.249.209 kanagawa-happy-town.ntt-east.co.jp\n121.119.249.193 akita-happy-town.ntt-east.co.jp\n121.119.249.201 nttob.jp\n121.119.249.211 akita-furusato-live.jp\n121.119.249.195 hokkaido-happy-town.ntt-east.co.jp\n121.119.249.195 h-happytown.biz\n121.119.249.230 ob-chiba.ntt-east.co.jp\n#\n# site-control-side host table (ariake)\n#\n192.168.163.2   admin1\n192.168.163.3   admin2\n192.168.163.5   log2\n192.168.163.60  mo-sw1\n10.162.255.7    dvd1\n10.160.122.51   eec1\n#\n192.168.162.228 asnm1\n#\n# site-control-side host table (urawa)\n#\n192.168.162.164 nm-u\n192.168.162.180 usnm1\n192.168.162.181 usadmin1        site.admin\n192.168.162.182 usadmin2\n10.162.255.241  usadmin5\n10.162.255.242  usadmin6\n10.160.122.204  srepo-c\n\n#\n##########\n# E-SITE(sendai) Host Table\n#\n219.103.157.1 senns1 senns1.ntt-east.co.jp\n219.103.157.2 senns2 senns2.ntt-east.co.jp\n219.103.157.4 senvx1 senvx1.ntt-east.co.jp\n219.103.157.7 senmail1 senmail1.ntt-east.co.jp\n219.103.157.10 senmcrypt1 senmcrypt1.ntt-east.co.jp\n#\n# evx4 increase construction\n# 2007/12/10\n#\n121.119.250.47  evx4    evx4.enoc.east.ntt.co.jp\n192.168.163.19  mo-sw4\n192.168.162.229 asnm1n\n192.168.162.186 usnm1n\n192.168.163.34  asmsw1\n192.168.163.44  fh-ra\n\n# cat /etc/nsswitch.conf\n#\n# /etc/nsswitch.conf\n#\n# An example Name Service Switch config file. This file should be\n# sorted with the most-used services at the beginning.\n#\n# The entry '[NOTFOUND=return]' means that the search for an\n# entry should stop if the search in the previous entry turned\n# up nothing. Note that if the search failed due to some other reason\n# (like no NIS server responding) then the search continues with the\n# next entry.\n#\n# Valid entries include:\n#\n#       nisplus                 Use NIS+ (NIS version 3)\n#       nis                     Use NIS (NIS version 2), also called YP\n#       dns                     Use DNS (Domain Name Service)\n#       files                   Use the local files\n#       db                      Use the local database (.db) files\n#       compat                  Use NIS on compat mode\n#       hesiod                  Use Hesiod for user lookups\n#       [NOTFOUND=return]       Stop searching if not found so far\n#\n\n# To use db, put the "db" in front of "files" for entries you want to be\n# looked up first in the databases\n#\n# Example:\n#passwd:    db files nisplus nis\n#shadow:    db files nisplus nis\n#group:     db files nisplus nis\n\npasswd:     files\nshadow:     files\ngroup:      files\n\n#ZAKI 検証環境では上のようにしておく、実際にはいか\npasswd:     files sss\nshadow:     files\ngroup:      files sss\n\n\n#hosts:     db files nisplus nis dns\nhosts:      files dns\n\n# Example - obey only what nisplus tells us...\n#services:   nisplus [NOTFOUND=return] files\n#networks:   nisplus [NOTFOUND=return] files\n#protocols:  nisplus [NOTFOUND=return] files\n#rpc:        nisplus [NOTFOUND=return] files\n#ethers:     nisplus [NOTFOUND=return] files\n#netmasks:   nisplus [NOTFOUND=return] files\n\nbootparams: nisplus [NOTFOUND=return] files\n\nethers:     files\nnetmasks:   files\nnetworks:   files\nprotocols:  files\nrpc:        files\nservices:   files\n\nnetgroup:   nisplus\n\npublickey:  nisplus\n\n#automount:  files nisplus\nautomount:  files\n#ZAKI automount:  files sss こっちが本物\naliases:    files nisplus\n\n# more /etc/passwd\nwebuser:x:9080:5000::/etc/httpd:/sbin/nologin\nbsc_gh:x:5001:5000::/export/home1/htdocs/bsc:/sbin/nologin\ncsd:x:5002:5000::/export/home1/htdocs/csd:/sbin/nologin\nana9768:x:5004:5000::/export/home1/htdocs/pvc-ana:/sbin/nologin\nesreport:x:5005:5000::/export/home1/htdocs/es-report:/sbin/nologin\npvccas:x:5007:5000::/export/home1/htdocs/cas:/sbin/nologin\ndiver001:x:5009:5000::/export/home1/htdocs/diversity:/sbin/nologin\nephelio:x:5010:5000::/export/home1/htdocs/ephelio:/sbin/nologin\ntest:x:5999:5000::/export/home1/htdocs/test:/sbin/nologin\ngyoumu07:x:5008:5000::/export/home1/htsdocs/gyoumukansa:/sbin/nologin\n\n# more after_chkconfig_gwww.txt\nNetworkManager  0:off   1:off   2:off   3:off   4:off   5:off   6:off\nabrt-ccpp       0:off   1:off   2:on    3:on    4:on    5:on    6:off\nabrtd           0:off   1:off   2:on    3:on    4:on    5:on    6:off\nacpid           0:off   1:off   2:on    3:on    4:on    5:on    6:off\natd             0:off   1:off   2:on    3:on    4:on    5:on    6:off\nauditd          0:off   1:off   2:on    3:on    4:on    5:on    6:off\nautofs          0:off   1:off   2:on    3:on    4:on    5:on    6:off\nblk-availability        0:off   1:on    2:off   3:off   4:off   5:off   6:off\ncertmonger      0:off   1:off   2:on    3:on    4:on    5:on    6:off\ncgconfig        0:off   1:off   2:off   3:off   4:off   5:off   6:off\ncgred           0:off   1:off   2:off   3:off   4:off   5:off   6:off\ncpuspeed        0:off   1:on    2:on    3:on    4:on    5:on    6:off\ncrond           0:off   1:off   2:on    3:on    4:on    5:on    6:off\ncups            0:off   1:off   2:off   3:off   4:off   5:off   6:off\ndnsmasq         0:off   1:off   2:off   3:off   4:off   5:off   6:off\nhaldaemon       0:off   1:off   2:on    3:on    4:on    5:on    6:off\nhtcacheclean    0:off   1:off   2:off   3:off   4:off   5:off   6:off\nhttpd           0:off   1:off   2:on    3:on    4:on    5:on    6:off\nip6tables       0:off   1:off   2:off   3:off   4:off   5:off   6:off\niptables        0:off   1:off   2:on    3:on    4:on    5:on    6:off\nirqbalance      0:off   1:off   2:on    3:on    4:on    5:on    6:off\nkdump           0:off   1:off   2:off   3:off   4:off   5:off   6:off\nlvm2-monitor    0:off   1:on    2:on    3:on    4:on    5:on    6:off\nmcelogd         0:off   1:off   2:on    3:on    4:on    5:on    6:off\nmdmonitor       0:off   1:off   2:off   3:off   4:off   5:off   6:off\nmessagebus      0:off   1:off   2:on    3:on    4:on    5:on    6:off\nnetconsole      0:off   1:off   2:off   3:off   4:off   5:off   6:off\nnetfs           0:off   1:off   2:on    3:on    4:on    5:on    6:off\nnetwork         0:off   1:off   2:on    3:on    4:on    5:on    6:off\nnfs             0:off   1:off   2:off   3:off   4:off   5:off   6:off\nnfslock         0:off   1:off   2:on    3:on    4:on    5:on    6:off\nntpd            0:off   1:off   2:on    3:on    4:on    5:on    6:off\nntpdate         0:off   1:off   2:on    3:on    4:on    5:on    6:off\nnumad           0:off   1:off   2:off   3:off   4:off   5:off   6:off\noddjobd         0:off   1:off   2:off   3:off   4:off   5:off   6:off\nportreserve     0:off   1:off   2:on    3:on    4:on    5:on    6:off\npostfix         0:off   1:off   2:off   3:off   4:off   5:off   6:off\npppoe-server    0:off   1:off   2:off   3:off   4:off   5:off   6:off\npsacct          0:off   1:off   2:off   3:off   4:off   5:off   6:off\nquota_nld       0:off   1:off   2:off   3:off   4:off   5:off   6:off\nrdisc           0:off   1:off   2:off   3:off   4:off   5:off   6:off\nrestorecond     0:off   1:off   2:off   3:off   4:off   5:off   6:off\nrhnsd           0:off   1:off   2:off   3:off   4:off   5:off   6:off\nrhsmcertd       0:off   1:off   2:off   3:off   4:off   5:off   6:off\nrngd            0:off   1:off   2:off   3:off   4:off   5:off   6:off\nrpcbind         0:off   1:off   2:on    3:on    4:on    5:on    6:off\nrpcgssd         0:off   1:off   2:off   3:off   4:off   5:off   6:off\nrpcsvcgssd      0:off   1:off   2:off   3:off   4:off   5:off   6:off\nrsyslog         0:off   1:off   2:on    3:on    4:on    5:on    6:off\nsaslauthd       0:off   1:off   2:off   3:off   4:off   5:off   6:off\nsmartd          0:off   1:off   2:off   3:off   4:off   5:off   6:off\nsnmpd           0:off   1:off   2:on    3:on    4:on    5:on    6:off\nsnmptrapd       0:off   1:off   2:off   3:off   4:off   5:off   6:off\nspice-vdagentd  0:off   1:off   2:off   3:off   4:off   5:off   6:off\nsshd            0:off   1:off   2:off   3:off   4:off   5:off   6:off\nsssd            0:off   1:off   2:on    3:on    4:on    5:on    6:off\nsysstat         0:off   1:on    2:on    3:on    4:on    5:on    6:off\nudev-post       0:off   1:on    2:on    3:on    4:on    5:on    6:off\nwdaemon         0:off   1:off   2:off   3:off   4:off   5:off   6:off\nwinbind         0:off   1:off   2:off   3:off   4:off   5:off   6:off\nwpa_supplicant  0:off   1:off   2:off   3:off   4:off   5:off   6:off\nxinetd          0:off   1:off   2:on    3:on    4:on    5:on    6:off\nypbind          0:off   1:off   2:off   3:off   4:off   5:off   6:off\n\nxinetd ベースのサービス:\n        chargen-dgram:  off\n        chargen-stream: off\n        daytime-dgram:  off\n        daytime-stream: off\n        discard-dgram:  off\n        discard-stream: off\n        echo-dgram:     off\n        echo-stream:    off\n        rexec:          off\n        rlogin:         off\n        rsh:            off\n        rsync:          off\n        sshd:           on\n        tcpmux-server:  off\n        time-dgram:     off\n        time-stream:    off\n\nmore /etc/rsyslog.conf\n# rsyslog v5 configuration file\n\n# For more information see /usr/share/doc/rsyslog-*/rsyslog_conf.html\n# If you experience problems, see http://www.rsyslog.com/doc/troubleshoot.html\n\n#### MODULES ####\n\n$ModLoad imuxsock # provides support for local system logging (e.g. via logger command)\n$ModLoad imklog   # provides kernel logging support (previously done by rklogd)\n#$ModLoad immark  # provides --MARK-- message capability\n\n# Provides UDP syslog reception\n#$ModLoad imudp\n#$UDPServerRun 514\n\n# Provides TCP syslog reception\n#$ModLoad imtcp\n#$InputTCPServerRun 514\n\n\n#### GLOBAL DIRECTIVES ####\n\n# Use default timestamp format\n$ActionFileDefaultTemplate RSYSLOG_TraditionalFileFormat\n\n# File syncing capability is disabled by default. This feature is usually not required,\n# not useful and an extreme performance hit\n#$ActionFileEnableSync on\n\n# Include all config files in /etc/rsyslog.d/\n$IncludeConfig /etc/rsyslog.d/*.conf\n\n\n#### RULES ####\n# Log all kernel messages to the console.\n# Logging much else clutters up the screen.\n#kern.*                                                 /dev/console\n\n# Log anything (except mail) of level info or higher.\n# Don't log private authentication messages!\nif $fromhost-ip =='127.0.0.1' and \\n        $msg contains 'IPTABLES_INPUT_LOG' and \\n        ( \\n           $syslogfacility-text == 'kern' and \\n           $syslogseverity-text == 'debug' \\n        ) \\nthen                                                    /var/log/iptables.log\n*.info;mail.none;authpriv.none;cron.none                /var/log/messages\n\n# The authpriv file has restricted access.\nauthpriv.*                                              /var/log/secure\n\n# Log all the mail messages in one place.\nmail.*                                                  -/var/log/maillog\n\n\n# Log cron stuff\ncron.*                                                  /var/log/cron\n\n# Everybody gets emergency messages\n*.emerg                                                 *\n\n# Save news errors of level crit and higher in a special file.\nuucp,news.crit                                          /var/log/spooler\n\n# Save boot messages also to boot.log\nlocal7.*                                                /var/log/boot.log\n\n# remote_syslog\n#*.err;kern.debug;daemon.notice;mail.crit        @10.159.213.12:514\n#mail.info                                      @10.159.213.12:514\n\n# ### begin forwarding rule ###\n# The statement between the begin ... end define a SINGLE forwarding\n# rule. They belong together, do NOT split them. If you create multiple\n# forwarding rules, duplicate the whole block!\n# Remote Logging (we use TCP for reliable delivery)\n#\n# An on-disk queue is created for this action. If the remote host is\n# down, messages are spooled to disk and sent when it is up again.\n#$WorkDirectory /var/lib/rsyslog # where to place spool files\n#$ActionQueueFileName fwdRule1 # unique name prefix for spool files\n#$ActionQueueMaxDiskSpace 1g   # 1gb space limit (use as much as possible)\n#$ActionQueueSaveOnShutdown on # save messages to disk on shutdown\n#$ActionQueueType LinkedList   # run asynchronously\n#$ActionResumeRetryCount -1    # infinite retries if host is down\n# remote host is: name/ip:port, e.g. 192.168.0.1:514, port optional\n#*.* @@remote-host:514\n# ### end of the forwarding rule ###\n\n# A template to for higher precision timestamps + severity logging\n$template SpiceTmpl,"%TIMESTAMP%.%TIMESTAMP:::date-subseconds% %syslogtag% %syslogseverity-text%:%msg:::sp-if-no-1st-sp%%msg:::drop-last-lf%\n\n"\n\n:programname, startswith, "spice-vdagent"       /var/log/spice-vdagent.log;SpiceTmpl\n\nauth.debug      @10.159.213.12\nauthpriv.debug  @10.159.213.12\ncron.debug      @10.159.213.12\ndaemon.debug    @10.159.213.12\nkern.debug      @10.159.213.12\nmail.debug      @10.159.213.12\nsyslog.debug    @10.159.213.12\nuser.debug      @10.159.213.12\nuucp.debug      @10.159.213.12\nlocal0.debug    @10.159.213.12\nlocal1.debug    @10.159.213.12\nlocal2.debug    @10.159.213.12\nlocal3.debug    @10.159.213.12\nlocal4.debug    @10.159.213.12\nlocal5.debug    @10.159.213.12\nlocal6.debug    @10.159.213.12\nlocal7.debug    @10.159.213.12\n\nmore snmp/snmpd.conf\n# Following entries were added by HP Insight Management Agents at\n#      Fri Nov 11 16:49:41 JST 2011\ndlmod cmaX /usr/lib64/libcmaX64.so\nrwcommunity kra-esight 127.0.0.1\nrocommunity esight 127.0.0.1\nrwcommunity kra-esight default\nrocommunity esight default\ntrapcommunity esight\ntrapsink 10.159.213.9 esight\ntrapsink 10.159.216.4 esight\n# ---------------------- END --------------------\n)
#memo(https://www1.ntt-east.ipxp/gyoumukansa/guide-top/kaizen2007.html\nhttps://www1.ntt-east.ipxp/gyoumukansa/guide-top/kansa2007.html\nhttp://www1.ntt-east.ipxp/csd/syogai/index.html\nhttp://www1.ntt-east.ipxp/csd/syonai/index.html\nhttp://www1.ntt-east.ipxp/csd/kosyo/framepage1.htm\nhttp://www1.ntt-east.ipxp/csd/shien/home.html\nhttp://www1.ntt-east.ipxp/csd/tougou-setsubi/download1.htm\nhttp://www1.ntt-east.ipxp/cas/02/members/index.htm\nhttp://www1.ntt-east.ipxp/cas/02/restdata/index.htm\nhttp://www1.ntt-east.ipxp/diversity/\n\nmore /etc/sysconfig/network-scripts/route-eth1\n10.159.212.0/255.255.255.0      via 10.159.213.129\n10.159.213.0/255.255.255.0      via 10.159.213.129\n10.159.214.0/255.255.255.0      via 10.159.213.129\n10.159.215.0/255.255.255.0      via 10.159.213.129\n10.159.216.0/255.255.255.0      via 10.159.213.129\n10.40.255.128/255.255.255.192   via 10.159.213.129\n10.0.0.0/255.255.255.0          via 10.159.213.129\n172.16.0.0/255.255.0.0          via 10.159.213.129\n\n# more /etc/hosts\n\n\n# cat /etc/nsswitch.conf\n#\n# /etc/nsswitch.conf\n#\n# An example Name Service Switch config file. This file should be\n# sorted with the most-used services at the beginning.\n#\n# The entry '[NOTFOUND=return]' means that the search for an\n# entry should stop if the search in the previous entry turned\n# up nothing. Note that if the search failed due to some other reason\n# (like no NIS server responding) then the search continues with the\n# next entry.\n#\n# Valid entries include:\n#\n#       nisplus                 Use NIS+ (NIS version 3)\n#       nis                     Use NIS (NIS version 2), also called YP\n#       dns                     Use DNS (Domain Name Service)\n#       files                   Use the local files\n#       db                      Use the local database (.db) files\n#       compat                  Use NIS on compat mode\n#       hesiod                  Use Hesiod for user lookups\n#       [NOTFOUND=return]       Stop searching if not found so far\n#\n\n# To use db, put the "db" in front of "files" for entries you want to be\n# looked up first in the databases\n#\n# Example:\n#passwd:    db files nisplus nis\n#shadow:    db files nisplus nis\n#group:     db files nisplus nis\n\npasswd:     files\nshadow:     files\ngroup:      files\n\n#ZAKI 検証環境では上のようにしておく、実際にはいか\npasswd:     files sss\nshadow:     files\ngroup:      files sss\n\n\n#hosts:     db files nisplus nis dns\nhosts:      files dns\n\n# Example - obey only what nisplus tells us...\n#services:   nisplus [NOTFOUND=return] files\n#networks:   nisplus [NOTFOUND=return] files\n#protocols:  nisplus [NOTFOUND=return] files\n#rpc:        nisplus [NOTFOUND=return] files\n#ethers:     nisplus [NOTFOUND=return] files\n#netmasks:   nisplus [NOTFOUND=return] files\n\nbootparams: nisplus [NOTFOUND=return] files\n\nethers:     files\nnetmasks:   files\nnetworks:   files\nprotocols:  files\nrpc:        files\nservices:   files\n\nnetgroup:   nisplus\n\npublickey:  nisplus\n\n#automount:  files nisplus\nautomount:  files\n#ZAKI automount:  files sss こっちが本物\naliases:    files nisplus\n\n# more /etc/passwd\nwebuser:x:9080:5000::/etc/httpd:/sbin/nologin\nbsc_gh:x:5001:5000::/export/home1/htdocs/bsc:/sbin/nologin\ncsd:x:5002:5000::/export/home1/htdocs/csd:/sbin/nologin\nana9768:x:5004:5000::/export/home1/htdocs/pvc-ana:/sbin/nologin\nesreport:x:5005:5000::/export/home1/htdocs/es-report:/sbin/nologin\npvccas:x:5007:5000::/export/home1/htdocs/cas:/sbin/nologin\ndiver001:x:5009:5000::/export/home1/htdocs/diversity:/sbin/nologin\nephelio:x:5010:5000::/export/home1/htdocs/ephelio:/sbin/nologin\ntest:x:5999:5000::/export/home1/htdocs/test:/sbin/nologin\ngyoumu07:x:5008:5000::/export/home1/htsdocs/gyoumukansa:/sbin/nologin\n#useradd -u 9081 -g 5001 -d /opt/hp/hpsmh /sbin/nologin hpsmh\n普段、どのユーザアカウントでftpしていますか?\n# more after_chkconfig_gwww.txt\nNetworkManager  0:off   1:off   2:off   3:off   4:off   5:off   6:off\nabrt-ccpp       0:off   1:off   2:on    3:on    4:on    5:on    6:off\nabrtd           0:off   1:off   2:on    3:on    4:on    5:on    6:off\nacpid           0:off   1:off   2:on    3:on    4:on    5:on    6:off\natd             0:off   1:off   2:on    3:on    4:on    5:on    6:off\nauditd          0:off   1:off   2:on    3:on    4:on    5:on    6:off\nautofs          0:off   1:off   2:on    3:on    4:on    5:on    6:off\nblk-availability        0:off   1:on    2:off   3:off   4:off   5:off   6:off\ncertmonger      0:off   1:off   2:on    3:on    4:on    5:on    6:off\ncgconfig        0:off   1:off   2:off   3:off   4:off   5:off   6:off\ncgred           0:off   1:off   2:off   3:off   4:off   5:off   6:off\ncpuspeed        0:off   1:on    2:on    3:on    4:on    5:on    6:off\ncrond           0:off   1:off   2:on    3:on    4:on    5:on    6:off\ncups            0:off   1:off   2:off   3:off   4:off   5:off   6:off\ndnsmasq         0:off   1:off   2:off   3:off   4:off   5:off   6:off\nhaldaemon       0:off   1:off   2:on    3:on    4:on    5:on    6:off\nhtcacheclean    0:off   1:off   2:off   3:off   4:off   5:off   6:off\nhttpd           0:off   1:off   2:on    3:on    4:on    5:on    6:off\nip6tables       0:off   1:off   2:off   3:off   4:off   5:off   6:off\niptables        0:off   1:off   2:on    3:on    4:on    5:on    6:off\nirqbalance      0:off   1:off   2:on    3:on    4:on    5:on    6:off\nkdump           0:off   1:off   2:off   3:off   4:off   5:off   6:off\nlvm2-monitor    0:off   1:on    2:on    3:on    4:on    5:on    6:off\nmcelogd         0:off   1:off   2:on    3:on    4:on    5:on    6:off\nmdmonitor       0:off   1:off   2:off   3:off   4:off   5:off   6:off\nmessagebus      0:off   1:off   2:on    3:on    4:on    5:on    6:off\nnetconsole      0:off   1:off   2:off   3:off   4:off   5:off   6:off\nnetfs           0:off   1:off   2:on    3:on    4:on    5:on    6:off\nnetwork         0:off   1:off   2:on    3:on    4:on    5:on    6:off\nnfs             0:off   1:off   2:off   3:off   4:off   5:off   6:off\nnfslock         0:off   1:off   2:on    3:on    4:on    5:on    6:off\nntpd            0:off   1:off   2:on    3:on    4:on    5:on    6:off\nntpdate         0:off   1:off   2:on    3:on    4:on    5:on    6:off\nnumad           0:off   1:off   2:off   3:off   4:off   5:off   6:off\noddjobd         0:off   1:off   2:off   3:off   4:off   5:off   6:off\nportreserve     0:off   1:off   2:on    3:on    4:on    5:on    6:off\npostfix         0:off   1:off   2:off   3:off   4:off   5:off   6:off\npppoe-server    0:off   1:off   2:off   3:off   4:off   5:off   6:off\npsacct          0:off   1:off   2:off   3:off   4:off   5:off   6:off\nquota_nld       0:off   1:off   2:off   3:off   4:off   5:off   6:off\nrdisc           0:off   1:off   2:off   3:off   4:off   5:off   6:off\nrestorecond     0:off   1:off   2:off   3:off   4:off   5:off   6:off\nrhnsd           0:off   1:off   2:off   3:off   4:off   5:off   6:off\nrhsmcertd       0:off   1:off   2:off   3:off   4:off   5:off   6:off\nrngd            0:off   1:off   2:off   3:off   4:off   5:off   6:off\nrpcbind         0:off   1:off   2:on    3:on    4:on    5:on    6:off\nrpcgssd         0:off   1:off   2:off   3:off   4:off   5:off   6:off\nrpcsvcgssd      0:off   1:off   2:off   3:off   4:off   5:off   6:off\nrsyslog         0:off   1:off   2:on    3:on    4:on    5:on    6:off\nsaslauthd       0:off   1:off   2:off   3:off   4:off   5:off   6:off\nsmartd          0:off   1:off   2:off   3:off   4:off   5:off   6:off\nsnmpd           0:off   1:off   2:on    3:on    4:on    5:on    6:off\nsnmptrapd       0:off   1:off   2:off   3:off   4:off   5:off   6:off\nspice-vdagentd  0:off   1:off   2:off   3:off   4:off   5:off   6:off\nsshd            0:off   1:off   2:off   3:off   4:off   5:off   6:off\nsssd            0:off   1:off   2:on    3:on    4:on    5:on    6:off\nsysstat         0:off   1:on    2:on    3:on    4:on    5:on    6:off\nudev-post       0:off   1:on    2:on    3:on    4:on    5:on    6:off\nwdaemon         0:off   1:off   2:off   3:off   4:off   5:off   6:off\nwinbind         0:off   1:off   2:off   3:off   4:off   5:off   6:off\nwpa_supplicant  0:off   1:off   2:off   3:off   4:off   5:off   6:off\nxinetd          0:off   1:off   2:on    3:on    4:on    5:on    6:off\nypbind          0:off   1:off   2:off   3:off   4:off   5:off   6:off\n\nxinetd ベースのサービス:\n        chargen-dgram:  off\n        chargen-stream: off\n        daytime-dgram:  off\n        daytime-stream: off\n        discard-dgram:  off\n        discard-stream: off\n        echo-dgram:     off\n        echo-stream:    off\n        rexec:          off\n        rlogin:         off\n        rsh:            off\n        rsync:          off\n        sshd:           on\n        tcpmux-server:  off\n        time-dgram:     off\n        time-stream:    off\n\nmore /etc/rsyslog.conf\n# rsyslog v5 configuration file\n\n# For more information see /usr/share/doc/rsyslog-*/rsyslog_conf.html\n# If you experience problems, see http://www.rsyslog.com/doc/troubleshoot.html\n\n#### MODULES ####\n\n$ModLoad imuxsock # provides support for local system logging (e.g. via logger command)\n$ModLoad imklog   # provides kernel logging support (previously done by rklogd)\n#$ModLoad immark  # provides --MARK-- message capability\n\n# Provides UDP syslog reception\n#$ModLoad imudp\n#$UDPServerRun 514\n\n# Provides TCP syslog reception\n#$ModLoad imtcp\n#$InputTCPServerRun 514\n\n\n#### GLOBAL DIRECTIVES ####\n\n# Use default timestamp format\n$ActionFileDefaultTemplate RSYSLOG_TraditionalFileFormat\n\n# File syncing capability is disabled by default. This feature is usually not required,\n# not useful and an extreme performance hit\n#$ActionFileEnableSync on\n\n# Include all config files in /etc/rsyslog.d/\n$IncludeConfig /etc/rsyslog.d/*.conf\n\n\n#### RULES ####\n# Log all kernel messages to the console.\n# Logging much else clutters up the screen.\n#kern.*                                                 /dev/console\n\n# Log anything (except mail) of level info or higher.\n# Don't log private authentication messages!\nif $fromhost-ip =='127.0.0.1' and \\n        $msg contains 'IPTABLES_INPUT_LOG' and \\n        ( \\n           $syslogfacility-text == 'kern' and \\n           $syslogseverity-text == 'debug' \\n        ) \\nthen                                                    /var/log/iptables.log\n*.info;mail.none;authpriv.none;cron.none                /var/log/messages\n\n# The authpriv file has restricted access.\nauthpriv.*                                              /var/log/secure\n\n# Log all the mail messages in one place.\nmail.*                                                  -/var/log/maillog\n\n\n# Log cron stuff\ncron.*                                                  /var/log/cron\n\n# Everybody gets emergency messages\n*.emerg                                                 *\n\n# Save news errors of level crit and higher in a special file.\nuucp,news.crit                                          /var/log/spooler\n\n# Save boot messages also to boot.log\nlocal7.*                                                /var/log/boot.log\n\n# remote_syslog\n#*.err;kern.debug;daemon.notice;mail.crit        @10.159.213.12:514\n#mail.info                                      @10.159.213.12:514\n\n# ### begin forwarding rule ###\n# The statement between the begin ... end define a SINGLE forwarding\n# rule. They belong together, do NOT split them. If you create multiple\n# forwarding rules, duplicate the whole block!\n# Remote Logging (we use TCP for reliable delivery)\n#\n# An on-disk queue is created for this action. If the remote host is\n# down, messages are spooled to disk and sent when it is up again.\n#$WorkDirectory /var/lib/rsyslog # where to place spool files\n#$ActionQueueFileName fwdRule1 # unique name prefix for spool files\n#$ActionQueueMaxDiskSpace 1g   # 1gb space limit (use as much as possible)\n#$ActionQueueSaveOnShutdown on # save messages to disk on shutdown\n#$ActionQueueType LinkedList   # run asynchronously\n#$ActionResumeRetryCount -1    # infinite retries if host is down\n# remote host is: name/ip:port, e.g. 192.168.0.1:514, port optional\n#*.* @@remote-host:514\n# ### end of the forwarding rule ###\n\n# A template to for higher precision timestamps + severity logging\n$template SpiceTmpl,"%TIMESTAMP%.%TIMESTAMP:::date-subseconds% %syslogtag% %syslogseverity-text%:%msg:::sp-if-no-1st-sp%%msg:::drop-last-lf%\n\n"\n\n:programname, startswith, "spice-vdagent"       /var/log/spice-vdagent.log;SpiceTmpl\n\nauth.debug      @10.159.213.12\nauthpriv.debug  @10.159.213.12\ncron.debug      @10.159.213.12\ndaemon.debug    @10.159.213.12\nkern.debug      @10.159.213.12\nmail.debug      @10.159.213.12\nsyslog.debug    @10.159.213.12\nuser.debug      @10.159.213.12\nuucp.debug      @10.159.213.12\nlocal0.debug    @10.159.213.12\nlocal1.debug    @10.159.213.12\nlocal2.debug    @10.159.213.12\nlocal3.debug    @10.159.213.12\nlocal4.debug    @10.159.213.12\nlocal5.debug    @10.159.213.12\nlocal6.debug    @10.159.213.12\nlocal7.debug    @10.159.213.12\n\nmore snmp/snmpd.conf\n# Following entries were added by HP Insight Management Agents at\n#      Fri Nov 11 16:49:41 JST 2011\ndlmod cmaX /usr/lib64/libcmaX64.so\nrwcommunity kra-esight 127.0.0.1\nrocommunity esight 127.0.0.1\nrwcommunity kra-esight default\nrocommunity esight default\ntrapcommunity esight\ntrapsink 10.159.213.9 esight\ntrapsink 10.159.216.4 esight\n# ---------------------- END --------------------\n\n)

* 通信要件調査 [#bb446560]

* ctfrelay [#a72e6695]
delegate(TCP proxy)のこと。ftp経由先として使う。~
以下でダウンロードできる。実機が9.9.7なのでこれに合わせる。~
ftp://delegate.hpcc.jp/pub/DeleGate/old/

#pre{{
DeleGateビルド手順
2012.2.25 onoda


1.検証用DeleGate環境構築及び起動

(*) shellはbsh系を想定。

(1) 環境確認
$ who am i
ntte
$ pwd
/home/ntte/tmp
$ ls
delegate9.9.7.tar.gz

(2) tarballの展開
$ tar zxvf ./delegate9.9.7.tar.gz
$ ls -F
delegate9.9.7/ delegate9.9.7.tar.gz

(3) ビルド
$ cd ./delegate9.9.7
$ DGROOT=/tmp/delegate-ntte make

※ make の途中でデフォルトで持つADMINメールアドレスの入力を求められるが、デフォルトのまま、"y"で応答する。
(DeleGateのADMIN設定で明示的に指定するため、ここでは不要)

(4) ./src配下に実行形式"delegated"があることを確認
$ ls ./src/delegated
./src/delegated

(5) $DGROOT ディレクトリが作成されていることを確認
$ ls /tmp/delegate-ntte
/tmp/delegate-ntte/log /tmp/delegate-ntte/tmp

(6) dgbindのインストール
$ pwd
/home/ntte/tmp/delegate9.9.7
$ cd ./subin
$ chmod +x ./install.sh
$ make install

(7) dgbindインストール確認
ls /tmp/delegate-ntte/subin

(8) dgbindのpermissionを変更
$ cd /tmp/delegate-ntte/subin
$ su
# chown root dgbind
# chgrp ntte dgbind
# chmod 6550 dgbind
# exit

(9) DeleGate本体をインストール
$ cd /home/ntte/tmp/delegate9.9.7/src
$ cp delegated /tmp/delegate-ntte/bin(*)

 (*) 本ディレクトリ以外でも構わない。

(10) 検証用DeleGate設定ファイルの準備
 準備した設定ファイル(DeleGate起動ファイル)を適当なディレクトリに準備する。
 (DGROOTを/tmp/delegate-ntteで指定すること)

$ cd /home/ntte/bin
$ cp /hoge/delegated.init ./delegated

(11) 検証用DeleGateの起動
$ su
# /home/ntte/bin/delegated start


2.本番環境へのコピー
 検証が完了したdelegatedを/usr/local/bin 配下に格納する。

# mv /usr/local/bin/delegated /usr/local/bin/delegated.bak
# cp /path.to/delegated /usr/local/bin
# chown root:root /usr/local/bin/delegated
# chmod +x /usr/local/bin/delegated


以上
}}

* ツール [#i126eb17]
** 単体試験用 [#sabef5d9]
*** パラメータシート確認スクリプト(RHEL6用) [#n0b2b2e3]
 /nas/bin/check_parameter_sheet_RHEL6.sh

#pre{{
#------------------------------------
# 基本設定
#------------------------------------

## インストール情報

# OS
  [ /etc/issue ]
Red Hat Enterprise Linux Server release 6.7 (Santiago)
Kernel \r on an \m


# カーネルバージョン等
Linux gwww 2.6.32-573.3.1.el6.x86_64 #1 SMP Mon Aug 10 09:44:54 EDT 2015 x86_64 x86_64 x86_64 GNU/Linux

# マシン名
gwww

## ハードウェア情報

# メモリ
MemTotal:       16334296 kB
 
}}

#counter